How do you protect buildings and technology from the outside in?

Protected infrastructure.

Buildings, data centres and facilities are not protected by one measure, but by coordinated layers from the outside in.

In 60 seconds

  • Protection is built in zones from the outside in.
  • The KRITIS Umbrella Act has applied to physical resilience since 17 March 2026.
  • Access, video, intrusion detection, power and climate control work together.
Data centre with fence, camera on a pole and access door

4 areas, one concept.#

Outer shell

Site, fence, lighting and access roads are the first layer.

Building

Access, video and intrusion detection keep unauthorised people out and make incidents visible.

Technology

Power, climate control, fire protection and network connection must keep running during disruptions.

People and processes

Visitor rules, emergency plans and training keep the system alive.

Protection zones from the outside in.#

The more critical the area, the stricter the rules.

1 SiteFence, lighting, access road, cameras at the edge2 Building shellDoors, windows, intrusion detection, access at the entrance3 Security areaSeparation, multi-factor access, visitor escort4 Server room and racksRack lock, logging, environmental sensors
Four nested zones: each boundary has its own control.

KRITIS Umbrella Act.#

In force since 17 March 2026: protecting physical resilience.

For the first time, the KRITIS Umbrella Act requires operators of critical facilities nationwide and across sectors to take measures for their physical resilience. It complements NIS2, which mainly regulates cyber security.

  • 10 sectors, such as energy, transport, finance, health and drinking water.
  • Risk analysis for critical services and facilities.
  • Resilience measures and resilience plan, for example for emergency preparedness, physical protection and staff.
  • Registration and reporting of relevant incidents.
  • Management responsibility for implementation and supervision.

4 goals of the measures

Prevent incidents, ensure physical protection, respond appropriately and limit consequences, restore operations.

For data centres, standards such as EN 50600 or ISO/IEC 22237 are often used. As of November 2026, for guidance only, not legal advice. More on NIS2 on the NIS2 page.

How the building blocks work together.#

AreaBuilding blocksLink
AccessSeparation, multi-factor access, visitor escort, logsAccess control
VideoPerimeter and entrances, analytics, secure storageVideo surveillance
Intrusion detectionDoor contacts, motion detectors, alarm forwardingEvent triggers camera image
Fire protectionEarly detection, extinguishing technology, fire compartmentsEmergency release of doors
Power and climateUPS, backup power, redundant coolingAlert to monitoring
Network connectionTwo independent paths, separate routesHigh-security networks
Environmental sensorsTemperature, humidity, water, smokeMonitoring

Resistance classes for doors and windows.#

How long does an element withstand a break-in attempt?

ClassType of burglar and toolsResistance timeSuitable for
RC 1 NOpportunistic burglar using physical force (kicking, shoulder charge)not specifiedSide rooms without burglary risk
RC 2 N / RC 2Opportunistic burglar with simple tools such as screwdriver, pliers, wedge3 minutesFlat and house, recommended by the police as a minimum standard
RC 3Additionally a second screwdriver and crowbar5 minutesCommercial premises, offices, technical rooms
RC 4Experienced burglar, additionally saw, hammer, axe, cordless drill10 minutesServer rooms, storage with valuables
RC 5Additionally power tools such as drill, jigsaw, angle grinder15 minutesHigh-value technology, data centres
RC 6Additionally high-performance power tools20 minutesVery high risks, special areas

Resistance classes according to DIN EN 1627 for doors, windows and closures. Important: the class only applies if element, installation and fixing match. The time is the pure working time on the element.

UPS calculator.#

How much power and battery does your equipment need during a power cut?

Rough guidance, no planning and no legal advice. Everything runs only in your browser.

Check: infrastructure.#

6 questions about your site.

What applies?
0 of 6
Next step

Rough guidance, no audit and no legal advice. Your selection stays in your browser.

Frequently asked questions.#

Who counts as an operator of critical facilities?

Law and regulation define this by sector and thresholds. Operators are registered. Have your classification checked by experts, ideally with your trade association or specialist advice.

Does a small business need perimeter protection?

Not to the depth of a data centre. But server room, access, fire protection and backup power make sense for small businesses too and can be implemented with manageable effort.

What does "state of the art" mean?

It means current, proven procedures and standards available on the market. The level keeps evolving, so regular review is part of it.

How are access and video connected?

An access event can display or store a camera image. This helps with alarms and investigations, but needs a data protection and permissions concept.

Thinking through your site?

Tell me which area you want to secure, and we will add to the content.

Learning path Protecting buildingsStep 1 of 5Next: Access media